Sign In | Join Free | My disqueenfrance.com
China XI'AN BEICHENG ELECTRONICS CO.,LTD logo
XI'AN BEICHENG ELECTRONICS CO.,LTD
The Best Quality, The Best Service!
Site Member

5 Years

Home > Multifunction Process Calibrator >

VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator

XI'AN BEICHENG ELECTRONICS CO.,LTD
Contact Now

VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator

  • 1
  • 2

Brand Name : VICTOR

Model Number : VICTOR 71B

Certification : CE

Place of Origin : CHINA

MOQ : 1pcs

Price : USD60/pc

Payment Terms : T/T, Western Union, L/C, Paypal

Supply Ability : 1000pcs available

Delivery Time : 5 to 30 days

Packaging Details : 12pcs/Carton; Carton Size: 430mm*350mm*22.50mm

Color : Blue and Black

Size : 205 × 95 × 42 mm

Product Name : Signal Generator

Model No. : VICTOR 71B

Packing Details : 12pcs/Carton; Carton Size: 430mm*350mm*22.50mm

Accuracy : 0.2% accuracy

Weight : Approx. 500 g (including batteries)

Power supply : one 9 V alkaline battery (6LR61)

Contact Now

VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator

VICTOR 71B Generator Thermocouple Current Voltage Portable Signal Process Calibrator V/mA Analog Transmitter Source Simulator

Features:

1. V/mA calibrator

2. 24V loop power supply

3. Simulate transmitter output

4. 8 (R, S, B, K, E, J, T and N) thermocouple output

4. Measurea and source 20mA current

5. Output 10V DC voltage

6. Flash light function

Measurement function:

DC mV range: -10~100mV; resolution: 100uV, accuracy: ±(0.2%+4).

DCV range: -5~30V;resolution: 10mV, accuracy: ±(0.2%+4).

DC mA range: 0~22mA; resolution: 0.01mA, accuracy: ±(0.2%+4).

Loop supply: 24V; Max current: 25mA, accuracy: 10%.

Thermocouple (R, S, B, K, E, J, T and N): 0-1350℃ (K); resolution: 1℃,

Source output function:

DC mV output range: 0~110.0mV, resolution: 100uV, accuracy:±(0.2%+4).

DCV output range: 0~10.00V, resolution: 10mV, accuracy: ±(0.2%+4).

DCA output range: 0~22.00mA, resolution: 0.01mA, accuracy: ±(0.2%+4).

Simulate: 0~22.00mA, resolution: 0.001mA, accuracy: ±(0.2%+4).

Thermocouple output range: R: 0-1760℃, S: 0-1760℃, B: 400-1800℃, K: 0-1350℃, E: 0-700℃, J: 0-950℃, T: 0-400℃, N: 0-1300℃. Resolution: 1℃., Accuracy: ±0.5%+3℃

Backlight: Yes

Display area: 45mm*26mm

Battery:3 *1.5V 7 battery

Dimensions (with jacket): 147×75 ×42 mm

Technical Data

Project VICTOR 71A VICTOR 71B
SOURCE DC millivolt Range 0~110mV 0~110mV
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 100uV 100uV
DC voltage Range 0 ~ 10V 0 ~ 10V
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 10mV 10mV
DC current Range 0~22mA 0~22mA
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 0.01mA 0.01mA
Sink current Range 0~22mA 0~22mA
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 0.01mA 0.01mA
External power supply 5 ~ 28V 5 ~ 28V
Thermocouple Range 8 types(R/S/K/E/J/T/B/N)
Basic accuracy 0.2%+4dgt
Resolution 1℃
MEASURE DC millivolt Range -10~110mV -10~110mV
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 100uV 100uV
DC voltage Range -5~30V -5~30V
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 10mV 10mV
DC current Range 0~22mA 0~22mA
Basic accuracy 0.2%+4dgt 0.2%+4dgt
Resolution 0.01mA 0.01mA
Loop power Range 24V 24V
Basic accuracy 10% 10%
Limit current 25mA 25mA
Thermocouple Range 8types(R/S/K/E/J/T/B/N)
Basic accuracy 0.2%+4dgt
Resolution 1℃
Other functions Manual Step Output
Automatic Waveform Output
Standard Quantity Per Carton 12pcs 12pcs
Standard Carton Measurement 430mm*350mm*22.50mm 430mm*350mm*22.50mm
Standard Carton Cross Weight 7Kg 7Kg


Product Tags:

VICTOR 71B Rtd Temperature Calibrator

      

VICTOR 71B Signal Process Calibrator

      

Portable Rtd Temperature Calibrator

      
China VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator wholesale

VICTOR 71B Rtd Temperature Calibrator Portable Signal Process Calibrator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: XI'AN BEICHENG ELECTRONICS CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0